PH Sensor Kit for Water
Including 18% GST. Tax invoice with every order.
This one is out of stock right now. Ask the counter when it's due back.
Ask for a restock date on WhatsApp- Stocked at our Bengaluru counter, not drop-shipped — checked against your order before packing.
- GST tax invoice on every order. Add your GSTIN at checkout.
- Cash on delivery on orders under ₹5,000. Returns follow our return policy.
The PH Sensor Kit for water is designed for industrial and real-time online pH value monitoring. It can be easily interfaced with microcontrollers like Arduino, and is built for simple and convenient practical applications with long life. The sensor probe uses a sensitive glass membrane with low impedance, which allows for fast response and excellent thermal stability. This type of pH sensor kit is useful for monitoring pH levels in water treatment plants, laboratories, and other industrial settings.
Instructions for use:
Instructions for using the Analog PH Sensor Kit for water.
- Placing the sensor probe vertically and keeping it for a long time before using will help ensure accurate readings.
- It’s important to rinse the sensor probe tube in deionized water and dab it with a tissue paper before immersing it in the test solution.
- The device will take approximately 30 to 40 seconds to stabilize and give the results.
- Before placing the probe in the storage solution, it is important to rinse the probe tip in deionized water, dab it with a dry tissue paper, and then place it in the storage cap. This will help to remove any residual sample or contaminants from the probe and to keep it in good condition between uses.
- This will help keep the probe in good condition between uses.
- It’s also important to calibrate the device before each use, and to use the appropriate storage solution for the probe as per manufacturer’s instructions.
Important Notes:
- The sensor board is calibrated for the pH probe provided with the kit, calibration is required if the pH sensor probe is changed.
- It’s also important to note that the results obtained by this sensor are directly proportional to the temperature of the solution.
- The pH sensor probe tube tip is very sensitive and should not be touched with hands and cannot be placed on the ground.
- It’s important to handle the probe with care to avoid damage.
- The bulb type tip is very fragile and should be kept in the storage solution, and if not used for a long period of time and to ensure its longevity store in the solution.
- It is also important to follow the instruction manual provided with the kit and to use the appropriate solutions for cleaning and storage as per manufacturer’s instructions.
Package Includes :
1 x PH Sensor Circuit Board
1 x PH Electrode Probe
1 x 2Pin RMC Cable
1 x Manual
Key features
- Industry pH Electrode with BNC Connector
- PH Interface ( 2 foot patch )
- Power Indicator LED
- BNC Connector suitable for most PH meter and controller.
- This PH sensor is calibrated @ 24 degree centigrade on room temperature.
- Module Power
- DC 9.00V 1A
- Measuring Range
- 0-14PH
- Accuracy
- ± 0.1pH (24 )
- Response Time
- 1min
- Output
- Analog values in the range of (0.5V to 3V)
- Alkali Error
- 0.2PH
- Internal Resistance
- 250MO
- Response Time
- <1min
- Operating Temperature
- 0-60°
- Terminal Blocks
- BNC plug
- Suitable for wide range of application
- Aquariums, Hydroponics, Laboratory etc.
- Calibrated values are
- PH4 = 1.5V, PH7 = 2.0V and PH9 = 2.5V.
Same-day dispatch
Orders confirmed before 10:00 AM IST, Monday to Saturday, leave the counter that morning.
Bengaluru
Delivered the next working day after dispatch.
Rest of India
Delivered in 2–5 working days by Blue Dart, DTDC, TPC India.
Often wired up with it.
1/2 Inch Water Flow Sensor YF-S201
SRK-00165 In stock
Soil Moisture Sensor Module
SRK-00167 In stock
Capacitive Soil Moisture Sensor V1.2
SRK-00434 In stock
TDS Meter Digital Water Tester
SRK-001663 In stock
Water Level Sensor Module
SRK-00164 In stockBuying for a batch of projects?
Send the quantity and we'll quote against live stock with a delivery date we can hold.